Cross-Over Combinations for Safety Valves
Type SAVA2 COMBI and Type SAVA2 SOLO
- Durable due to free of cavity design and protected sealing surfaces
- Reliable during continuous operation and cross-over process
- Flow-optimized with full cross section
Cross-Over Combinations for Safety Valves
Type SAVA2 COMBI and Type SAVA2 SOLO
- Durable due to free of cavity design and protected sealing surfaces
- Reliable during continuous operation and cross-over process
- Flow-optimized with full cross section
Sealing Systems
Design characteristics
- full-flow, round bore cross section max. 3 % Pressure loss – no Valve float
- Valve sealing surfaces permanently protected from media
- Error-proof operation
- Same flow coefficient – regardless of the flow path
Options
- Actuation: Lever or gearbox
- Clearly visible position indicator
- Coded shaft connection (incorrect assembly prevented)
Sealing Systems
Design characteristics
- Full-flow, round bore cross section
- Max. 3 % Pressure loss – No Safety valve float
- Valve sealing surfaces permanently protected from media by PTFE-Sleeve
- Error-proof operation
- Same flow coefficient – regardless of the flow path
Options
- Actuation: Lever or gearbox
- Clearly visible position indicator
- Coded shaft connection (incorrect assembly prevented)
Variants / Executions
Type SAVA2-SOLO
Cross-Over Valve for Safety Valves
- Vent to atmosphere (without backflow of blow-off media capacity)
ζ = 0,45
manual pressure relief valve – optional with pressure gauge
- Full-flow, round bore cross section
- Max. 3 % Pressure loss – no Safety valve float
- Valve sealing surfaces permanently protected from media by PTFE sleeve
- Error-proof operation
- Same flow coefficient – regardless of the flow path
free of cavities
PTFE sleeve
Actuation
- Lever or gearbox
- Clearly visible position indicator
- Coded shaft connection (incorrect assembly prevented)
Cross-over action for 3-Way Plug Valve
Pos. 1
Safety valve 1
ζ = 0,45
Cross-over action
Amin guaranteed
- Least cross section Amin during the cross-over phase (Amin × 2 = 0,65 × A)
- full round bore
- good drag coefficient ζ = 0,85
Pos. 2
Safety valve 2
ζ = 0,45
Type SAVA2-COMBI
Cross-Over Combination for Safety Valves and handling of toxic media
- With backflow of toxic blow-off media
ζ = 0,45
manual pressure relief valve – optional with pressure gauge
- Full-flow, round bore cross section
- Max. 3 % Pressure loss – no Safety valve float
- Valve sealing surfaces permanently protected from media by PTFE slevee
- Free of cavities
- Error-proof operation
- Same flow coefficient – regardless of the flow path selected
Actuation
- One gearbox – no complex linkage required
- Safe Synchronized operation through a fixed shaft connection (no Chain!)
- Clearly visible position indicator
- Coded shaft connection (incorrect assembly prevented)
Cross-over action for 3-way and 4-way Plug Valve
Pos. 1
Safety valve 1
4-way Pluge Valve TOP
3-way Pluge Valve BOTTOM
ζ = 0,45
Cross-over action
Amin guaranteed
4-way Pluge Valve TOP
3-way Pluge Valve BOTTOM
- Least cross section Amin during the cross-over phase (Amin × 2 = 0,65 × A)
- full round bore
- good drag coefficient ζ = 0,85
Pos. 2
Safety valve 2
4-way Pluge Valve TOP
3-way Pluge Valve BOTTOM
ζ = 0,45